美国AMI氧气浓度传送器,AMI氧气分析仪,AMI微氧分析仪,AMI硫化氢分析仪中国代理商
- 产品规格:全系列产品
- 发货地:上海市徐汇区徐家汇街道
上海盈沣元器件有限公司专业销售美国AMI氧气浓度传送器,AMI氧气分析仪,AMI微氧分析仪,AMI硫化氢分析仪
如有需求,欢迎来电垂询 缑先生
美国AMI氧分析仪 美国AMI微量氧分析仪型号: Model 1000RS;Model 2001RS;Model 2001RSP;Model 2001RSM;Model 2001RSPM;Model 2010BR 美国AMI百分量氧分析仪型号: Model 60;Model 65;Model 70;Model 111;Model 201RS;Model 201RSP; Model 201RSM;Model 201RSPM;Model 210BR;Model 221;Model 221 美国AMI天然气氧分析仪型号: Model 2010B;Model 2010BR;Model 1000 S
美国AMI微量氧分析仪T-1微量的详细介绍
AMI仪器公司可提供性能优良、种类丰富的电化学氧气传感器, 能同时满足百分比含量测试和微量氧气(ppm)分析的应用,自成一体式的设计,更换极为方便。
| Model 60 | 氧气浓度变送器 | AMI(Advanced Micro Instruments Inc) |
| Model 65 | 氧气浓度变送器 | AMI(Advanced Micro Instruments Inc) |
| Model 111 | 手提式氧气分析仪 | AMI(Advanced Micro Instruments Inc) |
| Model 1000RS | 手提式微氧分析仪 | AMI(Advanced Micro Instruments Inc) |
| Model 210BR | 防爆壁挂式氧气分析仪 | AMI(Advanced Micro Instruments Inc) |
| Model 2010BR | 防爆壁挂式氧气分析仪 | AMI(Advanced Micro Instruments Inc) |
| Model 201RS | 盘面型氧气分析仪 | AMI(Advanced Micro Instruments Inc) |
| Model 2001RS | 盘面型氧气分析仪 | AMI(Advanced Micro Instruments Inc) |
| Model 201RSP | 盘面型氧气分析仪 | AMI(Advanced Micro Instruments Inc) |
| Model 201RSM | 盘面型氧气分析仪 | AMI(Advanced Micro Instruments Inc) |
| Model 201RSPM | 盘面型氧气分析仪 | AMI(Advanced Micro Instruments Inc) |
| Model 2001RSP | 盘面型微氧分析仪 | AMI(Advanced Micro Instruments Inc) |
| Model 2001RSM | 盘面型微氧分析仪 | AMI(Advanced Micro Instruments Inc) |
| Model 2001RSPM | 盘面型微氧分析仪 | AMI(Advanced Micro Instruments Inc) |
| Model 221R | 环境安全氧气监控器 | AMI(Advanced Micro Instruments Inc) |
| Model 70 | 盘面型氧气分析仪 | AMI(Advanced Micro Instruments Inc) |
MODEL 2010BR
Hazardous area permanent mount trace oxygen
- Trace oxygen - 0.0ppm to 25.0%
- Ultra-fast come-down H2S resistant sensor - up to 10ppm H2S resistant standard, 500ppm H2S resistant optional
- Hazardous area - CSA approved Class 1 Division 1 Group BCD
- Patented cell block minimizes sample volume, fittings and eliminates tubing.
- Compact size - easy installation
- AC/DC operation with very low power
- Integrated high-efficiency low power heater optional
- Precision state-of-the-art electronics
- Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
- Isolated 1-5V or 4-20mA output user selectable
- 10 user-selectable analog output ranges
- Complete ModBus RTU supported over RS485
- Data logging of oxygen readings, temperature and power supply voltage
- Calibration, power failure and brownout history
- Calibration factor indicates remaining sensor life
- Electrochemical Sensor Based Technology
MODEL 1000RS
Hazardous area portable trace oxygen
- Trace oxygen - 0.00ppm to 25.0%
- Ultra-fast come-down H2S resistant sensor - up to 10ppm H2S resistant standard, 500ppm H2S resistant optional
- Designed for hazardous area use
- Portable, battery powered
- Patented cell block minimizes sample volume, fittings and eliminates tubing.
- Integrated 4-way seal-off/bypass valve protects sensor from air contamination and purges system prior to measurement
- Fastest come-down (time to measurement) in the industry
- Precision state-of-the-art electronics
- Data logging of oxygen readings, temperature and power supply voltage
- 10 user-selectable analog output ranges
- Calibration history
- Calibration factor indicates remaining sensor life
- Electrochemical Sensor Based Technology
MODEL 210BR
Hazardous area permanent mount percent oxygen
- Percent oxygen - 0.00% to 25.0%
- H2S resistant sensor - up to 10ppm H2S resistant standard, 500ppm H2S resistant optional
- Hazardous area - CSA approved Class 1 Division 1 Group BCD
- Patented cell block minimizes sample volume, fittings and eliminates tubing.
- Compact size - easy installation
- AC/DC operation with very low power
- Integrated high-efficiency low power heater optional
- Precision state-of-the-art electronics
- Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
- Isolated 1-5V or 4-20mA output user selectable
- 4 user-selectable analog output ranges
- Complete ModBus RTU supported over RS485
- Data logging of oxygen readings, temperature and power supply voltage
- Calibration, power failure and brownout history
- Calibration factor indicates remaining sensor life
- Electrochemical Sensor Based Technology
MODEL 3010BR
Hazardous area permanent mount hydrogen sulfide
- Trace hydrogen Sulfide
- 0-200ppm standard, 0-2000ppm optional
- Hazardous area - CSA approved Class 1 Division 1 Group BCD
- Patented cell block minimizes sample volume, fittings and eliminates tubing.
- Compact size - easy installation
- AC/DC operation with very low power
- Integrated high-efficiency low power heater optional
- Precision state-of-the-art electronics
- Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
- Isolated 1-5V or 4-20mA output user selectable
- 4 user-selectable analog output ranges
- Complete ModBus RTU supported over RS485
- Data logging of hydrogen sulfide readings, temperature and power supply voltage
- Calibration, power failure and brownout history
- Calibration factor indicates remaining sensor life
- Electrochemical Sensor Based Technology
MODEL 3000RS
Hazardous area portable hydrogen sulfide
- Trace hydrogen Sulfide
- 0-200ppm standard, 0-2000ppm optional
- Designed for hazardous area use
- Portable, battery powered
- Patented cell block minimizes sample volume, fittings and eliminates tubing.
- Precision state-of-the-art electronics
- Data logging of hydrogen sulfide readings, temperature and battery voltage
- 4 user-selectable analog output ranges
- Calibration history
- Calibration factor indicates remaining sensor life
- Electrochemical Sensor Based Technology
MODEL 2001RS
General purpose permanent mount trace oxygen
- Trace oxygen - 0.00ppm to 25.0%
- Ultra-fast come-down sensor
- Positive pressure sample
- Patented cell block minimizes sample volume, fittings and tubing.
- Sensor sealed off on power failure - protects against air contamination
- Compact size - easy installation
- AC power 90/240VAC
- Precision state-of-the-art electronics
- Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
- Isolated 4-20mA output
- 10 user-selectable analog output ranges
- Complete ModBus RTU supported over RS485
- Data logging of readings, temperature and power supply voltage
- Calibration, power failure and brownout history
- Calibration factor indicates remaining sensor life
- Electrochemical Sensor Based Technology
MODEL 2001RSP
General purpose permanent mount trace oxygen. Atmospheric pressure sample source
- Trace oxygen - 0.00ppm to 25.0%
- Ultra-fast come-down sensor
- Ambient pressure sample
- Built-in pump
- Patented cell block minimizes sample volume, fittings and tubing.
- Sensor sealed off on power failure - protects against air contamination
- Compact size - easy installation
- AC power 90/240VAC
- Precision state-of-the-art electronics
- Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
- Isolated 4-20mA output
- 10 user-selectable analog output ranges
- Complete ModBus RTU supported over RS485
- Data logging of readings, temperature and power supply voltage
- Calibration, power failure and brownout history
- Calibration factor indicates remaining sensor life
- Electrochemical Sensor Based Technology
MODEL 201RS
General purpose permanent mount percent oxygen
- Percent oxygen - 0.00% to 25.0%
- Optional ranges 0-1000ppm, 0-50%, 0-100%
- Optional sensors for inert gas or High level CO2-containing gases
- Positive pressure sample
- Patented cell block minimizes sample volume, fittings and tubing.
- Compact size - easy installation
- AC power 90/240VAC
- Precision state-of-the-art electronics
- Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
- Isolated 4-20mA output
- 4 user-selectable analog output ranges
- Complete ModBus RTU supported over RS485
- Data logging of readings, temperature and power supply voltage
- Calibration, power failure and brownout history
- Calibration factor indicates remaining sensor life
- Electrochemical Sensor Based Technology
MODEL 201RSP
General purpose permanent mount percent oxygen. Atmospheric pressure sample source
- Percent oxygen - 0.00% to 25.0%
- Optional ranges 0-1000ppm, 0-50%, 0-100%
- Optional sensors for inert gas or High level CO2-containing gases
- Ambient pressure sample
- Built-in pump
- Patented cell block minimizes sample volume, fittings and tubing.
- Compact size - easy installation
- AC power 90/240VAC
- Precision state-of-the-art electronics
- Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
- Isolated 4-20mA output
- 4 user-selectable analog output ranges
- Complete ModBus RTU supported over RS485
- Datalogging of readings, temperature and power supply voltage
- Calibration, power failure and brownout history
- Calibration factor indicates remaining sensor life
- Electrochemical Sensor Based Technology
MODEL 2001RSM
Multichannel general purpose permanent mount trace oxygen
- Trace oxygen - 0.00ppm to 25.0%
- Ultra-fast come-down sensor
- Positive pressure sample
- Up to 5 sequenced sample inputs
- Patented cell block minimizes sample volume, fittings and tubing.
- Sensor sealed off on power failure - protects against air contamination
- Compact size - easy installation
- AC power 90/240VAC
- Precision state-of-the-art electronics
- Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
- Isolated 4-20mA output
- 10 user-selectable analog output ranges
- Complete ModBus RTU supported over RS485
- Data logging of readings, temperature and power supply voltage
- Calibration, power failure and brownout history
- Calibration factor indicates remaining sensor life
- Electrochemical Sensor Based Technology
MODEL 2001RSPM
Multichannel general purpose permanent mount trace oxygen for atmospheric pressure samples
- Trace oxygen - 0.00ppm to 25.0%
- Ultra-fast come-down sensor
- Ambient pressure sample
- Up to 5 sequenced sample inputs
- Built-in pump
- Patented cell block minimizes sample volume, fittings and tubing.
- Sensor sealed off on power failure - protects against air contamination
- Compact size - easy installation
- AC power 90/240VAC
- Precision state-of-the-art electronics
- Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
- Isolated 4-20mA output
- 10 user-selectable analog output ranges
- Complete ModBus RTU supported over RS485
- Data logging of readings, temperature and power supply voltage
- Calibration, power failure and brownout history
- Calibration factor indicates remaining sensor life
- Electrochemical Sensor Based Technology
MODEL 201RSM
Multichannel general purpose permanent mount percent oxygen
- Percent oxygen - 0.00% to 25.0%
- Optional ranges 0-1000ppm, 0-50%, 0-100%
- Optional sensors for inert gas or High level CO2-containing gases
- Positive pressure sample
- Up to 5 sequenced sample inputs
- Patented cell block minimizes sample volume, fittings and tubing.
- Compact size - easy installation
- AC power 90/240VAC
- Precision state-of-the-art electronics
- Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
- Isolated 4-20mA output
- 4 user-selectable analog output ranges
- Complete ModBus RTU supported over RS485
- Data logging of readings, temperature and power supply voltage
- Calibration, power failure and brownout history
- Calibration factor indicates remaining sensor life
- Electrochemical Sensor Based Technology
MODEL 201RSPM
Multichannel general purpose permanent mount percent oxygen for atmospheric pressure samples
- Percent oxygen - 0.00% to 25.0%
- Optional ranges 0-1000ppm, 0-50%, 0-100%
- Optional sensors for inert gas or High level CO2-containing gases
- Ambient pressure sample
- Up to 5 sequenced sample inputs
- Built-in pump
- Patented cell block minimizes sample volume, fittings and tubing.
- Compact size - easy installation
- AC power 90/240VAC
- Precision state-of-the-art electronics
- Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
- Isolated 4-20mA output
- 4 user-selectable analog output ranges
- Complete ModBus RTU supported over RS485
- Data logging of readings, temperature and power supply voltage
- Calibration, power failure and brownout history
- Calibration factor indicates remaining sensor life
- Electrochemical Sensor Based Technology
WATCHDOG
Low cost Division 2 area permanent mount trace oxygen
- Trace oxygen - 0.00ppm to 25.0%
- Ultra-fast come-down H2S resistant sensor - up to 10ppm H2S resistant standard, 500ppm H2S resistant optional
- Designed to meet Class 1 Division 2 hazardous area requirements
- Patented cell block minimizes sample volume, fittings and eliminates tubing.
- Compact size - easy installation
- DC operation with low power
- Precision state-of-the-art electronics
- Isolated 1-5V or 4-20mA output user selectable
- 10 user-selectable analog output ranges
- Complete ModBus RTU supported over RS485
- Data logging of oxygen readings, temperature and power supply voltage
- Calibration, power failure and brownout history
- Calibration factor indicates remaining sensor life
- Electrochemical Sensor Based Technology
MODEL 2001LC
General purpose rack mount trace oxygen Low cost
- Trace oxygen – 0.00ppm to 25.0%
- Ultra-fast come-down sensor
- Positive pressure sample
- Patented cell block minimizes sample volume, fittings and tubing.
- Compact size – easy installation
- DC power 10-28VDC
- Low power
- Precision state-of-the-art electronics
- Isolated 4-20mA output
- 10 user-selectable analog output ranges
- Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
- Electrochemical Sensor Based Technology
MODEL 221R
Area safety - permanent mount oxygen deficiency monitor
- Oxygen deficiency monitor, 0.00-25.0% O2
- CE marked, CSA approved
- Long life (10 year) ultra-stable zirconium oxide sensor
- Remote sensor option with digital communication
- Insensitive to barometric pressure or temperature changes - no false alarms
- AC power - 100-240V
- Internal battery backup
- Isolated 4-20mA output
- OSHA specified alarm set points with audible alarm and relay contacts
- Alarm upon enriched oxygen at 23.5%
- Data logging of readings, temperature and power supply voltage
- Calibration history
- Zirconium Oxide Sensor Based Technology
MODEL 221R W/REMOTE
Area safety – wall mount oxygen deficiency monitor
- Oxygen deficiency monitor, 0.00-25.0% O2
- CE marked, CSA approved
- Long life (10 year) ultra-stable zirconium oxide sensor in remotely mounted probe
- RS485 link between analyzer and probe for low interference
- Remote sensor option with digital communication
- Insensitive to barometric pressure or temperature changes – no false alarms
- AC power – 100-240V
- Internal battery backup
- Isolated 4-20mA output
- OSHA specified alarm set points with audible alarm and relay contacts
- Alarm upon enriched oxygen at 23.5%
- Data logging of readings, temperature and power supply voltage
- Calibration history
- Zirconium Oxide Sensor Based Technology
MODEL 70
General purpose percent oxygen
- Percent oxygen in non-flammable background gas, 0.00-25.0%
- Optional ranges 0-50%, 0-95%
- Long life (10 year) ultra-stable zirconium oxide sensor
- Insensitive to barometric pressure or temperature changes
- Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
- Isolated 0-1VDC, 1-5V or 4-20mA output
- 4 user-selectable analog output ranges
- Complete ModBus RTU supported over RS485
- Datalogging of readings, temperature and power supply voltage
- Calibration, power failure and brownout history
- Zirconium Oxide Sensor Based Technology
MODEL 65
Ultra-stable Percent oxygen probe
- Percent oxygen probe
- Long life ultra-stable zirconium oxide sensor
- 0-25% standard range
- 0-50% or 0-95% options
- Insensitive to barometric pressure or temperature changes
- Standard voltage output 0-2.5V
- Optional isolated 4-20mA output
- DC power 7-24V
- Zirconium Oxide Sensor Based Technology
MODEL 201LC
General purpose rack mount percent oxygen Low cost
- Percent oxygen – 0.00% to 25.0%
- Positive pressure sample
- Patented cell block minimizes sample volume, fittings and tubing.
- Compact size – easy installation
- DC power 10-28VDC
- Low power
- Precision state-of-the-art electronics
- Isolated 4-20mA output
- 4 user-selectable analog output ranges
- Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
- Electrochemical Sensor Based Technology
MODEL 111
Portable Ultra-stable Percent oxygen analyzer
- Percent oxygen in non-flammable background gas
- 0-25% standard range
- Optional ranges 0-50% or 0-95%
- Long life (10 year) ultra-stable zirconium oxide sensor
- Insensitive to barometric pressure or temperature changes
- Battery powered
- Data logging of readings, temperature and power supply voltage
- Calibration history
- Zirconium Oxide Sensor Based Technology
MODEL 111P
Portable Ultra-stable Percent oxygen analyzer. For ambient pressure samples
- Percent oxygen in non-flammable background gas
- 0-25% standard range
- 0-50% or 0-95% options
- Long life (10 year) ultra-stable zirconium oxide sensor
- Insensitive to barometric pressure or temperature changes
- Battery powered
- Long-life pump for ambient pressure samples
- Data logging of readings, temperature and power supply voltage
- Calibration history
- Zirconium Oxide Sensor Based Technology
MODEL 111B
Portable Ultra-stable Percent oxygen analyzer for aerospace
- Percent oxygen in non-flammable background gas
- 0-25% standard range
- 0-50% or 0-95% options
- Long life (10 year) ultra-stable zirconium oxide sensor
- Insensitive to barometric pressure or temperature changes
- Battery powered
- Long-life pump for ambient pressure samples
- Flame arrestors on inlet and outlet
- Suitable for use in Class 1 Division 2 Group CD hazardous areas
- Data logging of readings, temperature and power supply voltage
- Calibration history
- Zirconium Oxide Sensor Based Technology
MODEL 60
Low cost Percent oxygen probe
- Percent oxygen probe
- Ultra-low cost
- 0-25% standard range
- Optional ranges available
- Standard voltage output 0-2.5VDC
- DC power 7-24V
- Electrochemical Sensor Based Technology